Awarded contract

RQ0000010125 Epifluorescence Microscope

Details

Value
GBP 172,120.7
Duration
6 years
Topic
Fluorescent microscopes
Published
23 October 2023

Tender description

Intended uses (priority order): 1) Real-time imaging of cellular physiology using ion-sensitive fluorophores or similar probes (e.g. fura 2 and fluo dyes with ability for acquisition of fura 2 ratiometric images ≥1Hz) 2) General epifluorescence imaging of living cell cultures using a range of fluorescent dyes to image cellular structure and function (cell viability, mitochondrial function, ROS etc). Excitation/emission capabilities should cover standard range of fluorophores (e.g. DAPI, fluorescein, rhodamine etc). 3) General transmitted light and epifluorescence imaging of fixed / stained cell cultures and slide-mounted tissue sections Essential requirements: • Research-grade inverted microscope chassis, stage, transmitted light illumination, eyepieces etc • Microscope should be capable of phase and differential interference contrast transmitted light methods. • Objectives 10, 20, 40 and ~60 or 100x optimised for epifluorescence observation and DIC, 20 and 40x objectives optimised for UV excitation for Fura 2 (@340 & 380 nm, if different from standard epifluorescence objectives), additional 20 and 40x for phase contrast. • Epifluorescence light source to provide illumination for cellular physiology studies (excitation suitable for a range of dyes including fura 2) should include software controlled shutter, or equivalent, to control illumination and synchronise to image acquisition. • Epifluorescence light source for general epifluorescence imaging (2 and 3 above) if different • Ability to mount both epifluorescence illumination systems and switch between physiology and high-resolution epifluorescence imaging modes • Monochrome camera suitable for real-time imaging cellular physiology • Monochrome camera for high resolution general epifluorescence (if different from above) • Ability to mount both cameras and switch between physiology and high-resolution epifluorescence imaging modes • Image acquisition and analysis software suitable for running cellular physiology studies • Image acquisition and analysis software suitable for general epifluorescence studies. Ability to combine fluorescence images to produce composite images, ability to undertake image analysis/cytometry measurements of fluorescently labelled specimens. Desirable requirements: • Motorised control of microscope operation • Additional image analysis options for analysis of standard histopathology tissue sections Other: • If all capability is not possible on one microscope chassis then would consider two systems. This requirement will be on the defence sourcing portal (DSP) Additional information: How to apply - This notice can be found on the defence sourcing portal at this link: https://www.contracts.mod.uk/go/172903630186FEB197D9

Timeline

  1. Completed: Award date5 October 2023
  2. Completed: Award published23 October 2023
    Current notice
  3. Next: Contract expiry date5 October 2029in 3 years

About the buyer

Defence Science & Technology Laboratory is a public sector buyer in United Kingdom publishing tenders and awards on Stotles. Explore their procurement activity and find more opportunities like this one.

Relevant CPV codes

  • 38515200 · Fluorescent microscopes

AI insights

  • Is there a preferred supplier?
  • What are the buyers pain points?
  • What has the buyer previously procured?
  • What are the key requirements?
Sign-up to enrich

Decision makers

Connect with the people behind this procurement.

Contact nameJob titlePhone numberWork email
Head of Procurement+44 •••• ••••••
Commercial Director+44 •••• ••••••
Procurement Manager+44 •••• ••••••
Category Lead+44 •••• ••••••
Senior Buyer+44 •••• ••••••
Contracts Manager+44 •••• ••••••

Related buyers

Buyers similar to Defence Science & Technology Laboratory.

View all buyers

Win more public sector contracts

Track every UK and Ireland tender in one place — set up alerts, find decision-makers, and never miss an opportunity.