Awarded contract

Atmospheric gas analyser

Details

Supplier(s)
GeoGas Analytica
Value
EUR 84,390
Topic
Pollution-monitoring devices
Published
2 February 2026

Tender description

SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable). Lot 1: SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable).

Timeline

  1. Completed: Award published2 February 2026
    Current notice
  2. Completed: Award date12 March 2026

About the buyer

University of Edinburgh is a public sector buyer in United Kingdom publishing tenders and awards on Stotles. Explore their procurement activity and find more opportunities like this one.

Relevant CPV codes

  • 38344000 · Pollution-monitoring devices

AI insights

  • Is there a preferred supplier?
  • What are the buyers pain points?
  • What has the buyer previously procured?
  • What are the key requirements?
Sign-up to enrich

Decision makers

Connect with the people behind this procurement.

Contact nameJob titlePhone numberWork email
Head of Procurement+44 •••• ••••••
Commercial Director+44 •••• ••••••
Procurement Manager+44 •••• ••••••
Category Lead+44 •••• ••••••
Senior Buyer+44 •••• ••••••
Contracts Manager+44 •••• ••••••

Related topics

Topics related to Atmospheric gas analyser, ranked by notice volume.

View all topics

Related buyers

Buyers similar to University of Edinburgh.

View all buyers

Win more public sector contracts

Track every UK and Ireland tender in one place — set up alerts, find decision-makers, and never miss an opportunity.