Plant Resilience Chiller
Details
- Topic
- Heating, ventilation and air-conditioning installation work
- Published
- 16 January 2023
- Submission
- 24 February 2023
- Source
- uk:procontracts
Tender description
<p>A new single chiller is required to serve a back-up to an existing Daikin chiller. The system serves the building 1°C cooling coils located within 9 No. Dehumidifiers that maintain a set dew-point within existing clean & dry rooms. The current 1°C chiller circuit is supplied by a single chiller. This circuit supplies the 9 dehumidifier units which serve the cell assembly rooms to achieve the target dew point for this area. The single chiller does not have any back up unit or resilience to prevent the room conditions from being compromised. The requirement of this document is to implement a resilience chiller which will supply chilled water in the event of a failure on the current system and not provide additional capacity to the circuit. The system already has provision to install and additional chiller in parallel to the current asset. All the Mechanical and Electrical Services are being tendered on a performance basis for this project. The Contractor shall be responsible for the full adoption of the design concepts and principles provided, detailed design, installation and commissioning of all necessary building services to suit the building layouts and passive fabric principles. The Performance Specification details the design standards that shall be adhered to in the development of the design of the building services, including all passive measures set out by the Client’s team for the project. The performance specification should not be taken as being exhaustive, but it is indicative of the quality and standards required for the project. Note that the drawings issued with the tender are to illustrate the design concepts and principles to be fully adopted and developed into a fully detailed design at the start of the contract period prior to any services being installed on site. See Technical Performance Specification (Appendix 1), all the requirements are listed in detail within the document.</p> Keywords: Plant Chiller, Chiller, Cooling and ventilation equipment
Timeline
- Completed: Tender published16 January 2023Current notice
- Completed: Submission date24 February 2023
About the buyer
UK Battery Industrialisation Centre is a public sector buyer in United Kingdom publishing tenders and awards on Stotles. Explore their procurement activity and find more opportunities like this one.
Relevant CPV codes
- 45331000 · Heating, ventilation and air-conditioning installation work
Decision makers
Connect with the people behind this procurement.
| Contact name | Job title | Phone number | Work email |
|---|---|---|---|
| Head of Procurement | +44 •••• •••••• | ••••••••@uk-battery-industrialisation-centre.gov | |
| Commercial Director | +44 •••• •••••• | ••••••••@uk-battery-industrialisation-centre.gov | |
| Procurement Manager | +44 •••• •••••• | ••••••••@uk-battery-industrialisation-centre.gov | |
| Category Lead | +44 •••• •••••• | ••••••••@uk-battery-industrialisation-centre.gov | |
| Senior Buyer | +44 •••• •••••• | ••••••••@uk-battery-industrialisation-centre.gov | |
| Contracts Manager | +44 •••• •••••• | ••••••••@uk-battery-industrialisation-centre.gov |
21 similar open tenders
See more open tenders related to Plant Resilience Chiller.
- Open tender
Property Works
- Open tender
DPS
- Open tender
Housing Maintenance & Repair
- Open tender
Demand Management and Renewables
- Open tender
MoJ Minor Works Dynamic Purchasing System
Related topics
Topics related to Plant Resilience Chiller, ranked by notice volume.
- 15,001£1.2tn
- 4,088£269.5bn
Related buyers
Buyers similar to UK Battery Industrialisation Centre.
- 2,657£1.7bn
- 1,713£205.5bn
- 1,531£58.3bn
- 1,073£985.0m
- 949£2.3bn
- 900£690.3m
- 900£19.4bn
- 868£1.7bn
- 794£14.1bn
- 751£154.2m
Win more public sector contracts
Track every UK and Ireland tender in one place — set up alerts, find decision-makers, and never miss an opportunity.