Provision of Pulmonary Function Testing
Details
- Buyer
- Ministry of Defence
- Value
- GBP 583,000
- Topic
- Pulmonary specialists services
- Published
- 9 June 2022
- Submission
- 29 July 2022
- Source
- uk:find_a_tender
Tender description
In order to maintain the maximum number of Operationally effective Military divers , the Authority is required to provide Pulmonary Function Testing (PFT). This test, when required, is used to inform decision-making regarding fitness to undertake diving training and maintaining / returning Military divers to full diving fitness. Lot 1: An outline of the standard testing for divers includes, as a minimum but not limited to, the following: a. Medical history questionnaire; b. Targeted physical examination where applicable; c. Flow volume loop; d. Plethysmography e. Gas transfer; f. Exercise spirometry; g. β2 agonist reversibility. The current Association of Respiratory Technicians and Physiologists (ARTP) standards for the testing should be used wherever possible. For aspects of testing not covered by the ARTP standards, current best practice should be followed. An outline of the standard measurements include as a minimum, but not limited to: a. Dynamic lung volume measurement to include: Forced Expiratory Volume in 1 second (FEV 1), Forced Vital Capacity (FVC) and FEV1/FVC ratio ) IAW ARTP standards and using a spirometer that complies with ATS/ERS 2005, has both volume/time and flow/volume curves and a large enough printout to assess the quality of the blow. b. Dynamic lung volumes using body plethysmography (constant volume box) producing Flow Volume Loop (FVL). This should include subdivisions of the expiratory curve from the FVL, both numerically and with a visual trace. The inspiratory portion of the FVL should also be measured. Other measurements to include FVC, FEV1, Peak Expiratory Flow (PEF) and Forced Expiratory Flow (FEF) (25% 50% 75% and 25-75%) IAW ARTP standards. c. Diffusing Capacity of the Lungs for Carbon Monoxide (DLCO) IAW ARTP standards. d. Static lung volumes using body plethysmography including: Total Lung Capacity (TLC), Residual Volume (RV), Functional Residual Capacity (FRC), Vital Capacity (VC). Additionally, a comparison of TLC by plethysmography with the accessible volume from a Gas Transfer (GT) manoeuvre to give an indication of any sequestered intra-thoracic gas not in rapid communication with the exterior through the bronchial tree. e. FEV1 and PEFR both immediately, and after a period of 10 minutes, following 8 minutes exercise on a static bicycle (maximal effort) breathing dry diving gas. f. Spirometry post 5 milligram nebulised salbutamol (FEV1 and PEF Rate). It is anticipated there shall be up to 77 PFT tests per annum to be undertaken within 6 weeks of referral. Lot 1: An outline of the standard testing for divers includes, as a minimum but not limited to, the following: a. Medical history questionnaire; b. Targeted physical examination where applicable; c. Flow volume loop; d. Plethysmography e. Gas transfer; f. Exercise spirometry; g. β2 agonist reversibility. The current Association of Respiratory Technicians and Physiologists (ARTP) standards for the testing should be used wherever possible. For aspects of testing not covered by the ARTP standards, current best practice should be followed. An outline of the standard measurements include as a minimum, but not limited to: a. Dynamic lung volume measurement to include: Forced Expiratory Volume in 1 second (FEV 1), Forced Vital Capacity (FVC) and FEV1/FVC ratio ) IAW ARTP standards and using a spirometer that complies with ATS/ERS 2005, has both volume/time and flow/volume curves and a large enough printout to assess the quality of the blow. b. Dynamic lung volumes using body plethysmography (constant volume box) producing Flow Volume Loop (FVL). This should include subdivisions of the expiratory curve from the FVL, both numerically and with a visual trace. The inspiratory portion of the FVL should also be measured. Other measurements to include FVC, FEV1, Peak Expiratory Flow (PEF) and Forced Expiratory Flow (FEF) (25% 50% 75% and 25-75%) IAW ARTP standards. c. Diffusing Capacity of the Lungs for Carbon Monoxide (DLCO) IAW ARTP standards. d. Static lung volumes using body plethysmography including: Total Lung Capacity (TLC), Residual Volume (RV), Functional Residual Capacity (FRC), Vital Capacity (VC). Additionally, a comparison of TLC by plethysmography with the accessible volume from a Gas Transfer (GT) manoeuvre to give an indication of any sequestered intra-thoracic gas not in rapid communication with the exterior through the bronchial tree. e. FEV1 and PEFR both immediately, and after a period of 10 minutes, following 8 minutes exercise on a static bicycle (maximal effort) breathing dry diving gas. f. Spirometry post 5 milligram nebulised salbutamol (FEV1 and PEF Rate). It is anticipated there shall be up to 77 PFT tests per annum to be undertaken within 6 weeks of referral.
Timeline
- Completed: Tender published9 June 2022Current notice
- Completed: Submission date29 July 2022
About the buyer
Ministry of Defence is a public sector buyer in United Kingdom publishing tenders and awards on Stotles. Explore their procurement activity and find more opportunities like this one.
Relevant CPV codes
- 85121232 · Pulmonary specialists services
Decision makers
Connect with the people behind this procurement.
| Contact name | Job title | Phone number | Work email |
|---|---|---|---|
| Head of Procurement | +44 •••• •••••• | ••••••••@ministry-of-defence.gov | |
| Commercial Director | +44 •••• •••••• | ••••••••@ministry-of-defence.gov | |
| Procurement Manager | +44 •••• •••••• | ••••••••@ministry-of-defence.gov | |
| Category Lead | +44 •••• •••••• | ••••••••@ministry-of-defence.gov | |
| Senior Buyer | +44 •••• •••••• | ••••••••@ministry-of-defence.gov | |
| Contracts Manager | +44 •••• •••••• | ••••••••@ministry-of-defence.gov |
1 similar open tenders
See more open tenders related to Provision of Pulmonary Function Testing.
Related topics
Topics related to Provision of Pulmonary Function Testing, ranked by notice volume.
- 11,698£1.1tn
Related buyers
Buyers similar to Ministry of Defence.
- 724£1.3bn
- 666£133.0bn
- 627£159.4bn
- 433£8.1bn
- 326£7.3bn
- 320£1.3bn
- 270£1.1bn
- 251£890.6m
- 220£483.7m
- 177£221.9bn
Win more public sector contracts
Track every UK and Ireland tender in one place — set up alerts, find decision-makers, and never miss an opportunity.
