Closed tender

Maternity Generator replacement

Details

Value
GBP 80,080
Topic
Electric motors
Published
9 November 2020
Submission
24 November 2020

Tender description

The University Hospitals Birmingham NHS Foundation Trust wish to replace the existing low voltage diesel driven 255kVA rated Maternity Standby Generator at Heartlands Hospital with a new higher rated low voltage diesel driven 500kVA rated prime rated low voltage diesel driven generator set. The new 500KVA low voltage diesel driven generator shall be housed in the current Maternity Generator House. In addition to the above, the project works shall also to entail the following associated with the new Maternity low voltage diesel driven standby generator: -Remove and replace existing fuel pipework and connections from the existing low voltage diesel driven bulk fuel tank to the new standby generator, the existing fuel storage tanks shall be retained and re used under these works. -Provide & Install a new suitably rated floor standing Low Voltage Switchboard -Provide new manual transfer switch to select between the new Maternity Standby Generator and temporary generator connections. -Provide a temporary generator connection facility in suitable housing for the Maternity Block -Provide a temporary load bank connection facility in suitable housing for the Maternity Block -Provide load bank shedding contactor arrangement to disconnect Maternity Generator load bank supply upon main failure to enable the embedded generator to support the essential load. The location for the new low voltage diesel driven Maternity Standby Generator is as noted on the drawings. New automatic generator controls will be provided for the for the new low voltage diesel driven Maternity Standby Generator to ensure the generator supports the load on a mains failure within timescales prescribed within this document. The associated low voltage switchgear works comprise the supply and install of a new Low Voltage Switchboard and facilities for connecting a temporary resistive load bank for generator routine "on load" testing and connection of a temporary low voltage diesel driven generator should the embedded low voltage generator need be taken "off line" or fail. This project also includes all associated building works in the provision of an external lockable GRP Enclosure and a suitable base, installation of below ground cable ducts and making good / sealing penetrations on completion of the works. Additional information: Bravo Reference itt__31628 Tender responses should be submitted via the portal by 1300hrs on the 24/11/2020.

Timeline

  1. Completed: Tender published9 November 2020
    Current notice
  2. Completed: Submission date24 November 2020

About the buyer

University Hospitals Birmingham NHS Foundation Trust is a public sector buyer in United Kingdom publishing tenders and awards on Stotles. Explore their procurement activity and find more opportunities like this one.

Relevant CPV codes

  • 31110000 · Electric motors
  • 31122000 · Generator units
  • 31161000 · Parts for electrical motors and generators
  • 31220000 · Electrical circuit components
  • 42000000 · Industrial machinery

AI insights

  • Is there a preferred supplier?
  • What are the buyers pain points?
  • What has the buyer previously procured?
  • What are the key requirements?
Sign-up to enrich

Decision makers

Connect with the people behind this procurement.

Contact nameJob titlePhone numberWork email
Head of Procurement+44 •••• ••••••
Commercial Director+44 •••• ••••••
Procurement Manager+44 •••• ••••••
Category Lead+44 •••• ••••••
Senior Buyer+44 •••• ••••••
Contracts Manager+44 •••• ••••••

14 similar open tenders

See more open tenders related to Maternity Generator replacement.

Explore all open tenders

Win more public sector contracts

Track every UK and Ireland tender in one place — set up alerts, find decision-makers, and never miss an opportunity.