Awarded contract

Electric motors, generators and transformers

Details

Buyer
Energinet.dk
Supplier(s)
Topic
Electric motors, generators and transformers
Published
5 February 2016

Tender description

Energinet.dk has initiated purchase of 7 lots: — Lot 1: Frame agreement regarding 400 kV Variable Shunt Reactors. — Lot 2: Frame agreement regarding 400 kV Shunt Reactors. — Lot 3: Frame agreement regarding 235 kV Shunt Reactors and Variable Shunt Reactors. — Lot 4: Frame agreement regarding 410/235 kV, 500 MVA, Autotransformer. — Lot 5: Contract regarding 235 kV, 500 MVA, Phaseshifter transformer. — Lot 6: Contract regarding 32/225 kV, 220 MVA Offshore Step-up Transformers. — Lot 7: Contract regarding 245 kV GIS. Rated voltage: 235 kV. Rated power: Two different sizes and variation ranges. Size 1: non-variable 120 Mvar. Size 2: variable between 60 — 120 Mvar. Cooling: Oil-filled, naturally air-cooled (ONAN). The shunt reactors must be fully 3-phase energized during Factory Acceptance Test. Rated voltage: 410/235 kV ±10x1 % with a tertiary winding for local power supply. Rated power: 500 MVA Cooling: Oil-filled, naturally and forced air-cooled (ONAN/ONAF). Rated voltage: 235 kV Rated power: 500 MVA Number of units: 1 Cooling: Oil-filled, naturally air-cooled (ONAN). Rated voltage: 220/32 kV Rated power: 220 MVA Number of units: 4 Cooling: Oil-filled, naturally air-cooled (ONAN). Gas-Insulated Switchgear with single-breaker bays for offshore indoor installation Maximum voltage: 245 kV Number of substations: 2 Number of complete bays: 4 on each of the 2 substations with an optional 5th bay at 1 substation. Rated voltage: 400 kV Rated power: Two different variation ranges Size 1: variable between 50 — 110 Mvar Size 2: variable between 70 — 140 Mvar Cooling: Oil-filled, naturally air-cooled (ONAN) The shunt reactors must be fully 3-phase energized during Factory Acceptance Test. Rated voltage: 400 kV Rated power: 2 different sizes Size 1: 65 Mvar Size 2: 100 Mvar Cooling: Oil-filled, naturally air-cooled (ONAN) The shunt reactors must be fully 3-phase energized during Factory Acceptance Test.

Timeline

  1. Completed: Award date16 December 2015
  2. Completed: Award published5 February 2016
    Current notice

About the buyer

Energinet.dk is a public sector buyer in Denmark publishing tenders and awards on Stotles. Explore their procurement activity and find more opportunities like this one.

AI insights

  • Is there a preferred supplier?
  • What are the buyers pain points?
  • What has the buyer previously procured?
  • What are the key requirements?
Sign-up to enrich

Decision makers

Connect with the people behind this procurement.

Contact nameJob titlePhone numberWork email
Head of Procurement+44 •••• ••••••
Commercial Director+44 •••• ••••••
Procurement Manager+44 •••• ••••••
Category Lead+44 •••• ••••••
Senior Buyer+44 •••• ••••••
Contracts Manager+44 •••• ••••••

11 similar open tenders

See more open tenders related to Electric motors, generators and transformers.

Explore all open tenders

Finding public sector work shouldn't be hard

Make your next tender search effortless with Stotles. Set up alerts, find decision maker contacts and never miss a good-fit opportunity again.